root 中文
Independent Chassis 1 1 0
System Management > Firmware upgrade > Swi Help

1. You can upgrade the CPLD and BMC on the BMC plane, and upgrade service software on the Base and Fabric planes.

2. The total capacity of the /tmp directory to which an upgrade file is uploaded is .The available capacity is

3. The Base and Fabric planes must be restarted after upgraded to a later version, but patch installation does not require a restart.

4. Restarting a switching plane interrupts all links on the plane. Exercise caution and avoid restarting all switching planes at the same time.

5. Restarting the primary switching plane in a stack will restart all switching planes in the stack.

6. After switches are stacked on the Base or Fabric plane, you need to upgrade only the master switch in the stack. After the master switch is upgraded, it automatically upgrades the standby switch and slave switches.

7. Do not refresh the page or close the web browser during an upgrade.

8. Upgrading the CPLD of a switch module automatically restarts the BMC and switching plane. During the restart process, the BMC cannot perform system monitoring or management, and the switching plane cannot exchange data.

Switching plane
BMC Base Fabric
Upgrade File
0%
Slot Number Component Name Plane   Firmware Version   Progress Operation